Halland Instruments AS

Zinc production: pH analyzers for the effluent treatment plant.

Applications in other industries:

[Zinc production]
[Nickel production, chlorine process]
[Fertilizer industry]
[Nickel production, HPAL process]
[Alumina production]
[Titanium dioxide pigment prod.]
[Wastewater treatment]
[Cobalt production]
[Electroplating industry]
[Froth flotation, ore benefication]

Process description:
The plant receives effluent water from the leaching plant and the cell house and waste water from ponds. The currents enter a large collecting tank. The composition of the solution from this tank has a zinc content of 1-3 g/l. From this tank the effluent is fed to the effluent treatment plant where lime milk is added to neutralize the acid content and to precipitate the zinc. Sulphide is added to precipitate the cadmium. The process takes place in a string of four reaction tanks. The pH values are adjusted automatically with two regulators which controls two lime pumps which adds lime milk in the first two tanks. After the reaction tanks the solution flows to two thickeners. The pH value is also measured in the overflow of the thickeners.

Flow: 160 m³/h. (80 m³/h with one thickener in operation). pH range: 4-9 pH. Zinc content: 1-3 g/l. Temperature: 10-30 ° C. Number of pH analyzers: 6. Tanks: 4 tanks each with a capacity of ca. 150 m³. Number of thickeners: 2

Wastewater treatment tanks

The four reaction tanks, the analyzers are mounted in the red container.

 

 

 

waste water teatment instrument room

The 6 analyzers at the effluent treatment plant